AHI Carrier Catalog | Page 275

WATER-COOLED LIQUID CHILLERS  30XW-P ZE/30XW-V ZE Physical data 30XW-P ZE0301 30XW-P ZE0401 30XW-P ZE0451 30XW-P ZE0551 30XW-P ZE0601 273 5,31 5,69 1 2072/1953 2724/927 /1617 387 5,79 6,21 1 2981/2763 3059/936/ 1743 438 5,71 6,26 1 3020/2802 3059/936/ 1743 560 5,90 6,54 1 3912/3593 3290/1 065/ 1950 598 5,69 6,36 1 3947/3628 3290/1070/ 1950 V-Ph-Hz 400(+/-10%) -3-50 kW 0,05 -0,88 400(+/-10%) -3-50 0,05 0,90 400(+/-10%) -3-50 0,05 0,90 400(+/-10%) -3-50 0,05 0,90 400(+/-10%) -3-50 0,05 0,90 A A A 130 303 87 176 414 109 196 414 123 239 587 146 263 587 162 A A A ---- ---- ---- ---- ---- 30XW-P ZE0651 30XW-P ZE0801 30XW-P ZE0901 30XW-P ZE1001 30XW-P ZE1101 654 5,73 6,29 1 3965/3646 3290/1070/ 1950 789 5,80 6,87 2 6872/6218 4795/1039/ 1997 879 5,85 6,97 2 6950/6296 4795/1039/ 1997 1005 5,88 6,78 2 7542/6682 4730/1162/ 2051 1103 5,66 6,49 2 7752/6892 4730/1162/ 2051 V-Ph-Hz 400(+/-10%) -3-50 kW 0,05 -0,82 400(+/-10%) -3-50 0,05 0,89 400(+/-10%) -3-50 0,05 0,90 400(+/-10%) -3-50 0,05 0,90 400(+/-10%) -3-50 0,05 0,90 A A A 284 587 176 176 414 109 196 414 123 239 587 146 239 587 146 A A A ---- 176 414 109 196 414 123 196 414 123 239 587 146 30XW-P ZE Cooling 30XW-P ZE HEATING HEATING Standby Power: Power Factor: Amps (Un) Circuit 1 Maximum Current Start Up Current Current at Eurovent Conditions Circuit 2 Maximum Current Start Up Current Current at Eurovent Conditions Cooling Performance Information Cooling Capacity* Cooling Efficiency EER Seasonal Efficiency ESEER Number of Refrigerant Circuit Operating/Shipping Weight Unit Dimensions LxWxH Electrical Information Unit Voltage: Standby Power: Power Factor: Amps (Un) Circuit 1 Maximum Current Start Up Current Current at Eurovent Conditions Circuit 2 Maximum Current Start Up Current Current at Eurovent Conditions * kW kW/kW kW/kW -kg mm Cooling mode conditions: Evaporator water heat exchanger, entering/leaving water temperature 12°C/7°C, fouling factor 0 m² K/W. Condenser water heat exchanger, entering/leaving water temperature 30°C/35°C, fouling factor 0m² K/W. All performances are compliant with EN14511-3 : 2013. Sound power level according to ISO9614-1. Unit is outside of the scope of AHRI Water-Cooled Water Chilling Packages Using Vapor Compression Cycle Certification Program, but is rated in accordance with AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Preliminary product data for information only. Final product data will be submitted by Carrier to Eurovent company during 2016. C A R R I E R 2 0 1 6 / 2 0 1 7 275 AIR TREATMENT Electrical Information Unit Voltage: kW kW/kW kW/kW -kg mm CONTROLS Cooling Capacity* Cooling Efficiency EER Seasonal Efficiency ESEER Number of Refrigerant Circuit Operating/Shipping Weight Unit Dimensions LxWxH COOLING Performance Information