AHI Carrier Catalog | Page 266

Features and advantages COOLING Low energy consumption ■■ The 30XW-V/30XWHV was designed for high performance both at full load and at part load. Exceptional ESEER values set new benchmarks for low energy consumption. -- Eurovent energy class A -- Eurovent certified values per EN14511-3:2011: EER up to 5.5 and ESEER up to 8.0 -- EER up to 5.8 kW/kW and ESEER up to 9.5 kW/kW (gross adjusted performances, not taking into account the water pump and heat exchanger pressure drops, given as a reference for comparison). ■■ High energy efficiency -- Inverter-driven twin-rotor screw compressors allow precise capacity matching of building load changes and signifi-cantly reduce unit power input, especially at part-load. -- Flooded multi-pipe heat exchangers for increased heat exchange efficiency. -- Electronic expansion device permits operation at a lower condensing pressure and improved utilisation of the evaporator heat exchange surface. ■■ Optimised electrical performance All 30XW-V/30XWHV units comply with class 3 of standard EN61800-3. Category C3 refers to industrial environments. With option 282 category C2 compliance is possible. -- Inverter-driven motors ensure negligible start-up current (value is lower than the maximum unit current draw) Designed to support green ­building design ■■ Design teams increasingly focus on designing “green buildings” to address today's energy efficiency and environmental sustainability needs. The air conditioning system uses between 30% and 40% of the annual building energy consumption. Selection of the right air conditioning unit is one the main aspects to consider when designing a green building. For buildings with a variable load throughout the year 30XW-V/30XWHV units offer the solution to this important challenge. For more details refer to page 4. High reliability ■■ Inverter-driven screw compressors -- Industrial-type screw compressors with oversized bearings and motor cooled by suction gas. -- The inverter is optimised for each compressor motor to ensure reliable operation and easy maintenance. -- All compressor components are easily accessible on site minimising down-time. ■■ Refrigerant circuits -- Two independent refrigerant circuits (from 1000 kW upwards); the second one automatically takes over, if the first one develops a fault, maintaining partial cooling under all circumstances. ■■ Evaporator -- Electronic paddle-free flow switch. Auto-setting according to cooler size and fluid type. ■■ Auto-adaptive control -- Control algorithm prevents excessive compressor cycling -- Automatic compressor unloading in case of abnormally high condensing pressure or discharge temperature. 266 ■■ Exceptional endurance tests -- Partnerships with specialised laboratories and use of limit simulation tools (finite element calculation) for the design of critical components. -- Transport simulation test in the laboratory on a vibrating table and then on an endurance circuit (based on a military standard). Easy and fast installation ■■ Compact design -- The 30XW-V/30XWHV units are designed to offer compact dimensions for easy installation. -- With a width of approximately 1.25 m up to 1000 kW the units can pass through standard door openings and only require minimum floor space in the plant room. ■■ Simplified electrical connections -- Main disconnect switch with high trip capacity -- Transformer supply to the integrated control circuit (400/24 V) ■■ Simplified water connections -- Victaulic connections on the evaporator and condenser -- Practical reference marks for entering and leaving water connections -- Possibility to reverse the heat exchanger water inlet and outlet at the factory -- Possibilty to modify the number of heat exchanger passes ■■ Fast commissioning -- Systematic factory operation test before shipment Quick-test function for step-by-step verification of the instruments, expansion devices and compressors. Minimised operating sound levels ■■ The inverter technology used for the compressor motors minimises noise levels at part load operation. In twocompressor units at 25% of the maximum load the unit sound power level is reduced by 10 dB(A). ■■ Standard unit features include: -- Silencers on the compressor discharge line. -- Sound insulation on the components that are most subjected to radiated noise. ■■ Option 257 further reduces the global unit sound level. New inverter-driven Thunderbolt screw compressor C A R R I E R 2 0 1 6 / 2 0 1 7