VARIABLE-SPEED WATER-COOLED LIQUID CHILLERS
30XW-V 580-1710
No.
Description
Advantages
Use 30XW-V
JBus gateway
148B
Two-directional communication board
complying with JBus protocol
Connects the unit by communication
bus to a building management system
580-1710
LON gateway
148D
Two-directional communication board
complying with LON protocol
Connects the unit by communication
bus to a building management system
580-1710
Bacnet over IP gateway
149
Two-directional high-speed
communication using BACnet protocol
over Ethernet network (IP)
Easy and high-speed connection by
ethernet line to a building management
system. Allows access to multiple unit
parameters
580-1710
Condensing temperature
limitation
150B
Limitation of the maximum condenser
leaving water temperature to 45°C
Reduced maximum power input and
current absorption: power cables and
protection elements can therefore be
downsized
580-1710
Control for low condensing 152
temperature systems
Output signal (0-10 V) to control the
condenser water inlet valve
Simple installation: for applications
with cold water at condenser inlet (ex.
ground-source, groundwater-source,
superficial water-source applications)
the signal permits to control a 2 or
3-way valve to maintain condenser
water temperature (and so condensing
pressure) at acceptable values
580-1710
Energy Management
Module EMM
156
Control board with additional inputs/
outputs. See Energy Management
Module option chapter
Extended remote control capabilities
(Set-point reset, ice storage end,
demand limits, boiler on/off command...)
580-1710
Leak detection
159
0-10 V signal to report any refrigerant
leakage in the unit directly on the
controlller (the leak detector itself must be
supplied by the customer)
Immediate customer notification of
refrigerant losses to the atmosphere,
allowing timely corrective actions
580-1710
Compliance with Swiss
regulations
197
Additional tests on the water heat
exchangers: supply (additional of PED
documents) supplementary certificates
and test certifications
Conformance with Swiss regulations
580-1710
Low noise level
257
Evaporator and suction piping sound
insulation
3 dB(A) quiter than standard unit
580-1710
Welded evaporator water
connection kit
266
Victaulic piping connections with welded
joints
Easy installation
580-1710
Welded condenser water
connection kit
267
Victaulic piping connections with welded
joints
Easy installation
580-1710
Flanged evaporator water
connection kit
268
Victaulic piping connections with flanged
joints
Easy installation
580-1710
Flanged condenser water
connection kit
269
Victaulic piping connections with flanged
joints
Easy installation
580-1710
Thermal compressor
insulation
271
The compressor is covered with a thermal Prevents air humidity to condensate on
insulation layer
the compressor surface
580-1710
EMC classification C2, as
per EN 61800-3
282
Additional RFI filters on the unit power line Reduces electromagnetic interferences.
Increase the variable frequency drive
(VFD) immunity level according to first
environment (so called, residential
environment) requirements and allow its
compliancy with emissions level required
in category C2
580-1710
Fast Capacity Recovery
QM295
New software algorithms to allow quick
restart and fast loading while preserving
unit-reliability
Full capacity recovery in less than 5
minutes after power failure. Matches
requirements of typical critical missions
applications
580-1710
Carrier Connect
(BSS regions only)
298
3G router board
NOTE 1: Require option 149
NOTE 2: When more than one machine is
installed on site, only one of them shall be
equipped with
option 298 while all of them must be
equipped with option 149
NOTE 3: If a CARRIER-PSM is on site,
option 298 shall be integrated in the PSM
while option 149 is still mandatory for
each single unit.
Enabler for Carrier Connect service offer
580-1710
C
A
R
R
I
E
R
2
0
1
6
/
2
0
1
7
CONTROLS
AIR TREATMENT
HEATING HEATING
COOLING
Options
265