AHI Carrier Catalog | Page 265

VARIABLE-SPEED WATER-COOLED LIQUID CHILLERS  30XW-V 580-1710 No. Description Advantages Use 30XW-V JBus gateway 148B Two-directional communication board complying with JBus protocol Connects the unit by communication bus to a building management system 580-1710 LON gateway 148D Two-directional communication board complying with LON protocol Connects the unit by communication bus to a building management system 580-1710 Bacnet over IP gateway 149 Two-directional high-speed communication using BACnet protocol over Ethernet network (IP) Easy and high-speed connection by ethernet line to a building management system. Allows access to multiple unit parameters 580-1710 Condensing temperature limitation 150B Limitation of the maximum condenser leaving water temperature to 45°C Reduced maximum power input and current absorption: power cables and protection elements can therefore be downsized 580-1710 Control for low condensing 152 temperature systems Output signal (0-10 V) to control the condenser water inlet valve Simple installation: for applications with cold water at condenser inlet (ex. ground-source, groundwater-source, superficial water-source applications) the signal permits to control a 2 or 3-way valve to maintain condenser water temperature (and so condensing pressure) at acceptable values 580-1710 Energy Management Module EMM 156 Control board with additional inputs/ outputs. See Energy Management Module option chapter Extended remote control capabilities (Set-point reset, ice storage end, demand limits, boiler on/off command...) 580-1710 Leak detection 159 0-10 V signal to report any refrigerant leakage in the unit directly on the controlller (the leak detector itself must be supplied by the customer) Immediate customer notification of refrigerant losses to the atmosphere, allowing timely corrective actions 580-1710 Compliance with Swiss regulations 197 Additional tests on the water heat exchangers: supply (additional of PED documents) supplementary certificates and test certifications Conformance with Swiss regulations 580-1710 Low noise level 257 Evaporator and suction piping sound insulation 3 dB(A) quiter than standard unit 580-1710 Welded evaporator water connection kit 266 Victaulic piping connections with welded joints Easy installation 580-1710 Welded condenser water connection kit 267 Victaulic piping connections with welded joints Easy installation 580-1710 Flanged evaporator water connection kit 268 Victaulic piping connections with flanged joints Easy installation 580-1710 Flanged condenser water connection kit 269 Victaulic piping connections with flanged joints Easy installation 580-1710 Thermal compressor insulation 271 The compressor is covered with a thermal Prevents air humidity to condensate on insulation layer the compressor surface 580-1710 EMC classification C2, as per EN 61800-3 282 Additional RFI filters on the unit power line Reduces electromagnetic interferences. Increase the variable frequency drive (VFD) immunity level according to first environment (so called, residential environment) requirements and allow its compliancy with emissions level required in category C2 580-1710 Fast Capacity Recovery QM295 New software algorithms to allow quick restart and fast loading while preserving unit-reliability Full capacity recovery in less than 5 minutes after power failure. Matches requirements of typical critical missions applications 580-1710 Carrier Connect (BSS regions only) 298 3G router board NOTE 1: Require option 149 NOTE 2: When more than one machine is installed on site, only one of them shall be equipped with option 298 while all of them must be equipped with option 149 NOTE 3: If a CARRIER-PSM is on site, option 298 shall be integrated in the PSM while option 149 is still mandatory for each single unit. Enabler for Carrier Connect service offer 580-1710 C A R R I E R 2 0 1 6 / 2 0 1 7 CONTROLS AIR TREATMENT HEATING HEATING COOLING Options 265