AHI Carrier Catalog | Page 257

WATER-COOLED LIQUID CHILLERS  30XW 254-1762 Operating limits Entering temperature at start-up - 35.0°C Leaving temperature during operation 3.3°C* 20.0°C Entering/leaving temperature difference at full load 2.8 K 11.1 K Entering temperature at start-up 13.0°C** - Leaving temperature during operation 19.0°C** 50.0°C*** Entering/leaving temperature difference at full load 2.8 K 11.1 K Evaporator Condenser *** Units with option 150 30XW--/30XW-P Minimum Maximum Entering temperature at start-up - 35.0°C Leaving temperature during operation 3.3°C* 15.0°C Entering/leaving temperature difference at full load 2.8 K 11.1 K 13.0°C** - Leaving temperature during operation 23.0°C** 63.0°C Entering/leaving temperature difference at full load 2.8 K 11.1 K * ** For low-temperature applications, where the leaving water temperature is below 3.3°C, a frost protection solution must be used. Please refer to option 5 and option 6. For lower condenser temperatures, a water flow control valve m ust be used at the condenser (two or three-way valve). Please refer to option 152 to ensure the correct condensing temperature. 40 35 30 25 15 30XW-- (1154)/30XW-P (512-562-1012) Minimum Maximum - 35.0°C 15 20 Evaporator leaving water temperature, °C Minimum load limit approx. 15% 60 55 50 45 40 35 30 From approx. 60% to full load 25 20 Part load limit approx. 50% 0 5 10 15 20 Evaporator leaving water temperature, °C Minimum load limit approx. 30% 70 EG 5 Option 5 with ethylene glycol -6°C 15.0°C PG 5 Option 5 with propylene glycol -3°C 15.0°C EG 6 Option 6 with ethylene glycol -12°C 15.0°C PG 6 Option 6 with propylene glycol -8°C 15.0°C Entering/leaving temp. difference at full load 2.8 K 11.1 K*** Entering temperature at start-up 13.0°C** - Leaving temperature during operation 19.0/ 23.0°C** 55.0/ 63.0°C**** Entering/leaving temp. difference at full load 2.8 K 11.1 K Condenser * The operating range with evaporator leaving temperatures above 3°C is permitted, but the performances are not optimised. ** For lower condenser temperatures, a water flow control valve must be installed at the condenser (two-way or three-way). Please refer to option 152 to ensure the correct condensing temperature. *** Please refer to chapter 10.5 of the installation manual for the minimum recommended evaporator glycol flow rate. **** Depends on the conditions at the evaporator and the load conditions. Notes: Ambient temperatures: During storage and transport of the 30XW units (including by container) the minimum and maximum permissible temperatures are -20°C and 72°C (and 65°C for option 200). For more precise details refer to the unit selection program. I E R 2 0 1 6 / 2 0 1 7 Condenser leaving water temperature, °C Leaving temperature during operation* R 10 65 Entering temperature at start-up R 5 65 Evaporator A Part load limit approx. 35% 0 Options 5 and 6 Units with options 5 and 6 C From approx. 45% to full load 20 70 Condenser leaving water temperature, °C Entering temperature at start-up 45 Option 150 Evaporator Condenser 50 AIR TREATMENT ** For low-temperature applications, where the leaving water temperature is below 3.3°C, a frost protection solution must be used. Please refer to option 5 and option 6. For lower condenser temperatures, a water flow control valve must be used at the condenser (two or three-way valve). Please refer to option 152 to ensure the correct condensing temperature. Please refer to option 150 for applications with a high condenser leaving temperature (up to 63°C). 55 60 55 50 45 40 EG 6 35 PG 6 EG 5 30 PG 5 25 20 15 -15 -10 -5 0 5 10 15 Evaporator leaving glycol temperature, °C 20 CONTROLS * Standard units COOLING Maximum HEATING HEATING Minimum Condenser leaving water temperature, °C Standard 30XW-- and 30XW-P units Operating range permitted, but performances are not optimised Full load with option 5/6 and ethylene or propylene glycol Part load limit approx. 80% Part load limit approx. 50% Part load limit approx. 30% 257