AHI Carrier Catalog | Page 255

WATER-COOLED LIQUID CHILLERS  30XW 254-1762 Features and advantages ■■ Compressors -- Silencers on the discharge line. -- Silencers on the economiser return line. -- Acoustic insulation on the components that are most subjected to radiated noise. Easy and fast installation ■■ Compact design -- The 30XW units are designed to offer the most compact dimensions on the market. -- With a width of approximately 1 m up to 1600 kW the units can pass through standard door openings and only require minimum floor space in the plant room. ■■ Simplified electrical connections -- Main disconnect switch with high trip capacity -- Transformer to supply the integrated control circuit (400/24 V) ■■ Simplified hydronic connections -- Victaulic connections on the evaporator and condenser -- Practical reference marks for entering and leaving water connections -- Possibility to reverse the heat exchanger water inlet and outlet at the factory -- Possibilty to modify the number of heat exchanger passes ■■ Fast commissioning -- Systematic factory operation test before shipment -- Quick-test function for step-by-step verification of the instruments, expansion devices and compressors Environmentally balanced ■■ R-134a refrigerant -- HFC refrigerant with zero ozone depletion potential ■■ Leak-tight refrigerant circuit -- Reduction of leaks as no capillary tubes and flare connections are used -- Verification of pressure transducers and temperature sensors without transferring refrigerant charge -- Discharge line shut-off valve and liquid line service valve for simplified maintenance. C A R R I E R 2 0 1 6 / 2 0 1 7 Remote Management (Standard) ■■ Units with Touch Pilot control can be easily accessed from the internet, using a PC with an Ethernet connection. This makes remote control quick and easy and offers significant advantages for service operations. ■■ The 30XW also communicates with other building management systems via optional communication gateways. ■■ The 30XW is equipped with an RS485 serial port that offers multiple remote control, monitoring and diagnostic possibilities. Carrier offers a vast choice of control products, specially designed to contro l, manage and supervise the operation of an air conditioning system. Please consult your Carrier representative for more information. ■■ The following commands/visualisations are possible from remote connection: -- Condenser pumps control: a digital input allows verification of condenser water flow (the flow switch must be supplied by the installer) -- Start/stop of the machine -- Dual set-point management: through a dedicated contact is possible to activate a second set-point (example: unoccupied mode) -- Demand limit setting: to limit the maximum chiller capacity to a predefined value -- Operation visualization: indication if the unit is operating or if it’s in stand-by (no cooling load) -- alarm visualization. 255 COOLING HEATING HEATING Low operating sound levels ■■ Screw compressors -- Industrial-type screw compressors with oversized bearings and motor cooled by suction gas. -- All compressor components are easily accessible on site minimising down-time. -- Protection increased by an electronic board. ■■ Refrigerant circuit -- Two independent refrigerant circuits (from 1000 kW upwards); the second one automatically takes over, if the first one develops a fault, maintaining partial cooling under all circumstances. ■■ Evaporator -- Electronic paddle-free flow switch. Auto-setting according to cooler size and fluid type. ■■ Auto-adaptive control -- Control algorithm prevents excessive compressor cycling (Carrier patent) -- Automatic compressor unloading in case of abnormally high condensing pressure. ■■ Exceptional endurance tests -- Partnerships with specialised laboratories and use of limit simulation tools (finite element calculation) for the design of critical components. -- Transport simulation test in the laboratory on a vibrating table and then on an endurance circuit (based on a military standard). AIR TREATMENT ■■ Full load and part load energy efficiency that surpasses the industry average: -- Eurovent energy efficiency class “A” -- EER of up to 5.9 kW/kW (30XW-P) -- ESEER of up to 6.8 kW/kW (30XW-P) -- New twin-rotor screw compressor equipped with a high-efficiency motor and a variable capacity valve that permits exact matching of the cooling capacity to the load. -- Flooded multi-pipe evaporator and condenser for increased heat exchange efficiency. -- Electronic expansion device permitting operation at a lower condensing pressure and improved utilisation of the evaporator heat exchange surface. -- Economizer system with electronic expansion device for increased cooling capacity (30XW-P). Absolute reliability CONTROLS Superior operating economy