AHI Carrier Catalog | Page 236

Options ■■ High-pressure single or dual pump, evaporator ■■ Condenser hydronic module with variable-speed single or dual pump ■■ Heat pump (hot-water control) ■■ Electronic starter for reduced startup current ■■ RS485 communications and “CCN Clock Board” time schedule board ■■ Very low temperature glycol solution down to -10°C ■■ Field water connections at the unit top ■■ T en sizes with nominal cooling capacities from 109 to 315 kW. ■■ AquaSnap chillers with scroll compressors, digital auto-adaptive Pro-Dialog control and Non-ozone depleting refrigerant HFC-407C. ■■ Can be supplied with integrated hydronic evaporator and condenser modules, limiting the installation to simple operations such as the entering and leaving water piping connection. ■■ Intelligent control of condenser water pump speed and operation of glycol cooler (30RW) or air-cooled condenser fans (30RWA) to ensure reliable and economical operation. ■■ Quick electrical connections. ■■ Units can operate down to -20°C outside temperature. ■■ The variable-speed condenser water pump automatically adjusts the water flow rate to maintain the ideal condensing conditions. ■■ High-performance plate heat exchangers maximise the thermodynamic properties of refrigerant HFC-407C. From size 30RW 160 the evaporator and the condenser have two interlaced refrigerant circuits. ■■ Space-saving design. ■■ No plant room required – unit can be installed in a place that is open to the public, if local regulations permit. ■■ The refrigerant circuit is completely leak-proof. ■■ Used with Carrier 09 series glycol coolers or air-cooled condensers, supplied ready for installation with a control box. All control components are installed and tested in the factory. 30RW 30RWA Leaving condenser water temperature, °C Condensing temperature, °C Operating limits 52 50 45 40 C 35 B A 30 25 20 -10 -5 0 10 5 45 D 40 35 30 25 20 15 10 E 5 0 -5 -10 -15 -20 -10 -5 0 5 10 15 Leaving evaporator water temperature, °C Notes 30RW 1. Evaporator and condenser ∆T = 5 K 2. For 30RW units without hydronic module with an entering condenser water temperature below 20°C a three-way valve is required to allow operation, while maintaining the correct condensing temperature. 3. For 30RW units equipped with a hydronic module the minimum entering water temperature is -15°C. 4. Maximum leaving condenser water temperature is 52°C (at full load) A Standard unit with without antifreeze solution B Standard unit operation with the anti-freeze solution required and control configuration for a leaving water temperature down to 0°C. C Standard unit operation with the anti-freeze solution required and control configuration for a leaving water temperature down to -10°C. D Operation at high air temperature is based on the drycooler selected. E Operation at low air temperature is possible down to -20°C with a drycooler. 236 64 60 55 50 A 45 40 35 30 15 0 -5 -10 Leaving evaporator water temperature, °C 5 10 15 10 15 Leaving evaporator water temperature, °C Leaving remote condenser air temperature, °C Leaving drycooler air temperature, °C COOLING Features and advantages 50 45 B 40 35 30 25 20 C 15 10 5 0 D -5 -10 0 -5 -10 5 Leaving evaporator water temperature, °C Notes 30RWA 1. Evaporator ∆T = 5 K 2. Unit operation is limited by the maximum compressor condensing temperature of 64°C. A Standard unit operation with the anti-freeze solution required and special control configuration. B Operation at high air temperature is based on the condenser selected. C Operating range down to 0°C, if the air-cooled condenser is not equipped with a variable-speed head fan. D Extended operating range with variable-speed fan. C A R R I E R 2 0 1 6 / 2 0 1 7