AHI Carrier Catalog | Page 215

WATER-COOLED/CONDENSERLESS LIQUID CHILLERS 30WG/30WGA 020-090 Options Options No. Description Advantages Use 30WG/30WGA Low-temperature brine solution Soft starter 6 Covers specific applications such as ice storage and industrial processe Reduced compressor start-up current 30WG 020-090 25 Low temperature glycol solution production down to -12 °C with ethylene glycol Electronic compressor starter Master/slave operation 58 Optimised operation of two units connected in parallel with operating time equalisation External disconnect handle 70F Condenser insulation 86 Unit equipped with an additional field-installed leaving water temperature sensor, allowing master/slave operation of two units connected in parallel. The handle of the electrical disconnect switch is on the outside of the unit Thermal condenser insulation LP single-pump, evap. side 116T HP variable-speed singlepump, evap. side 116V JBus gateway 148B BacNet gateway 148C LON gateway 148D Low sound level 257 Very low sound level 258 Evaporator screw connection sleeves Condenser screw connection sleeves Welded evaporator connection sleeves Welded condenser connection sleeves LP single-pump, cond.side 264 267 270T HP variable-speed singlepump, cond. side 270V Unit stackable for operation 273 Customer water connection at the top of the unit Remote user interface 274 Customer water connection at the top of the unit User interface for remote installation 275 Filter drier with replaceable 277 solid core Safety hydraulic components, 293 evap. side Safety hydraulic components, 293A cond. side C A R R I E R 2 0 1 Filter the fine particles and eliminates humidity Screen filter, expansion tank and safety valve integrated in the evaporator hydronic module Screen filter, expansion tank and safety valve integrated in the evaporator hydronic module 6 / 2 0 1 7 COOLING 30WG 020-090 30WGA 020-090 Easy and fast installation, reduced power consumption of the pump 30WG 020-090 30WGA 020-090 Easy connection by communication bus to a building management system Easy connection by communication bus to a building management system Easy connection by communication bus to a building management system Reduced sound emissions 30WG 020-090 30WGA 020-090 30WG 020-090 30WGA 020-090 30WG 020-090 30WGA 020-090 30WG 020-090 30WGA 020-090 30WG 020-090 30WGA 020-090 30WG 020-090 30WGA 020-090 30WG 020-090 Reduced sound emissions Allows unit connection to a screw connector Allows unit connection to a screw connector Allows welding of customer ­connections to the unit Allows welding of customer ­connections to the unit Easy and fast installation 30WG 020-090 30WGA 020-090 30WG 020-090 30WG 020-090 Easy and fast installation, reduced power consumption of the pump 30WG 020-090 Reduced footprint size 30WG 020-090 30WGA 020-090 30WG 020-090 Reduced footprint size Remote control of the unit and its operating parameters Maintains the refrigerated circuit without humidity Easy and fast installation, operating safety Easy and fast installation, operating safety HEATING HEATING Easy and fast installation AIR TREATMENT 266 Optimisation for heating applications 30WG 020-090 30WGA 020-090 30WG 020-090 30WG 020-090 30WGA 020-090 30WGA 020-090 30WG 020-090 30WGA 020-090 30WG 020-090 CONTROLS 265 Evaporator hydronic module equipped with low pressure fixed-speed pump, drain valve, air vent and pressure sensors. Select option 293 for built-in safety hydraulic components. Evaporator hydronic module equipped with high-pressure variable-speed pump, drain valve, air vent and pressure sensors. Select option 293 for built-in safety hydraulic components. Two-directional communications board, complies with JBus protocol Two-directional communications board, complies with BacNet protocol Two-directional communications board, complies with Lon Talk protocol Compressor sound enclosure and sound insulation of ma in noise sources Enhanced sound insulation of main noise sources Evaporator inlet/outlet screw connection sleeves Condenser inlet/outlet screw connection sleeves Welded evaporator inlet/outlet connection sleeves Welded condenser inlet/outlet connection sleeves Condenser hydronic module equipped with low pressure fixed-speed pump, drain valve, air vent and pressure sensors. Select option 293A for built-in safety hydraulic components. Condenser hydronic module equipped with high-pressure variable-speed pump, drain valve, air vent and pressure sensors. Select option 293A for built-in safety hydraulic components. Unit stackable for operation Quick access to the unit disconnect switch 30WG 020-090 30WGA 020-090 30WG 020-090 30WGA 020-090 215