Unit with option 119 or with option 119 and option 81 30XA 902 1002 1112 1212 1312 1382 1402 1502 1702 1702 Power circuit Nominal power supply V-ph-Hz Control circuit 400-3-50 ± 10% 24 V via internal transformer Maximum start-up current* Circuit 1** A 902 905 954 587 587 772 772 905 954 815 Circuit 2** A - - - 772 772 772 772 587 587 815 Option 81 A - - - 1093 1139 1208 1238 1275 1321 760 COOLING Nominal start-up current*** Circuit 1** A 843 845 860 587 587 772 772 845 860 Circuit 2** A - - - 772 772 772 772 587 587 760 Option 81 A - - - 1031 1047 1113 1128 1122 1133 - Cosine Phi (maximum)**** 0.85 0.85 0.86 0.86 0.87 0.87 0.87 0.86 0.86 0.86 Cosine Phi (nominal)† 0.84 0.84 0.84 0.84 0.84 0.85 0.86 0.84 0.84 0.84 Maximum power input‡ Circuit 1** kW 369 372 435 186 216 262 284 405 435 356 Circuit 2** kW - - - 286 309 284 305 217 217 356 Option 81 kW - - - 471 525 544 584 622 652 - Nominal unit current draw† Circuit 1** A 511 511 541 259 275 341 356 527 546 446 Circuit 2** A - - - 360 393 356 386 273 273 446 Option 81 A - - - 619 668 697 742 800 820 - Maximum unit current draw (Un)‡ Circuit 1** A 629 635 734 321 367 436 466 688 734 596 Circuit 2** A - - - 470 508 466 501 367 367 596 Option 81 A - - - 790 875 902 967 1056 1102 - 582 588 689 - - - - - - 640 Option 231 Maximum unit current draw (Un – 10%)**** Circuit 1** A 677 683 790 340 389 472 504 740 790 Circuit 2** A - - - 508 539 504 532 395 395 640 Option 81 A - - - 847 928 976 1036 1135 1185 - * Instantaneous start-up current (operating current of the smallest compressor + fan current + locked rotor current in star connection of the largest compressor). Values obtained at operation with maximum unit power input. ** 30XA 1402 to 1702 units: circuit 1 supplies circuits A and B, circuit 2 supplies circuits C and D. 30XA 1112, 1212, 1312 and 1382 units: circuit 1 supplies circuit A, circuit 2 supplies circuit B. *** Instantaneous start-up current (operating current of the smallest compressor + fan current + locked rotor current in star connection of the largest compressor). Values obtained at standard Eurovent unit operating conditions: air 35 °C, water 12 / 7 °C **** Values obtained at operation with maximum unit power input. † Values obtained at standard Eurovent unit operating conditions: air 35 °C, water 12 / 7 °C ‡ Values obtained at operation with maximum unit power input. Values given on the unit name plate Notes: 1. Unit sizes 30XA 1112, 1212, 1312, 1382, 1402 to 1702 have two power connection points. 178 C A R R I E R 2 0 1 6 / 2 0 1 7