AIR-COOLED LIQUID CHILLERS 30XAS 242-482 Features and advantages ■■ Compressor -- Discharge dampers integrated in the oil separator (Carrier patent). -- Silencer on the economiser return line. -- Acoustic compressor and oil separator enclosure reducing radiated noise (option). ■■ Condenser section -- Condenser coils in V-shape with an open angle, allowing quieter air flow across the coil -- Low-noise 4th generation Flying Bird fans, made of a composite material (Carrier patent) are now even quieter and do not generate intrusive low-frequency noise -- Rigid fan mounting preventing start-up noise (Carrier patent) Easy and fast installation ■■ Integrated hydronic module (option) -- Centrifugal high-pressure dual water pump, with operating time balancing and automatic changeover to the back-up pump if a fault develops -- Water filter protecting the water pump against circulating debris -- High-capacity membrane expansion tank ensures pressurisation of the water circuit -- Thermal insulation and aluminium protection (option) -- Pressure sensor to check filter pollution and for direct numerical display of the water flow rate with an estimate of the instantaneous cooling capacity at the control interface -- Water flow control valve ■■ Simplified electrical connections -- Main disconnect switch with high trip capacity -- Transformer to supply the integrated control circuit (400/24 V) ■■ Fast commissioning -- Systematic factory operation test before shipment -- Quick-test function for step-by-step verification of the instruments, expansion devices, fans and compressor C A R R I E R 2 0 1 6 / 2 0 1 7 ■■ Screw compressor -- Industrial-type screw compressor with oversized bearings and motor cooled by suction gas -- All compressor components are easily accessible on site minimising down-time -- Protection increased by an electronic board ■■ Air condenser All aluminium micro-channel heat exchangers (MCHE) with high corrosion resistance. The all aluminium design eliminates the formation of galvanic currents between aluminium and copper that cause coil corrosion in saline or corros ive environments ■■ Evaporator Thermal insulation with aluminium sheet finish for perfect resistance to external aggression (mechanical and UV protection) ■■ Auto-adaptive control -- Control algorithm prevents excessive compressor cycling (Carrier patent) -- Automatic compressor unloading in case of abnormally high condensing pressure. If condenser coil fouling or fan failure occurs, the AquaForce continues to operate, but at reduced capacity ■■ Exceptional endurance tests -- Partnerships with specialised laboratories and use of limit simulation tool s (finite element calculation) for the design of critical components. -- Transport simulation test in the laboratory on a vibrating table. The test is based on a military standard and equi-valent to 4000 km by truck. -- Salt mist corrosion resistance test in the laboratory for increased corrosion resistance COOLING Absolute reliability HEATING HEATING Low operating sound levels ■■ R-134a refrigerant -- Refrigerant of the HFC group with zero ozone depletion potential -- 30% reduction in the refrigerant charge through the use of micro-channel heat exchangers ■■ Leak-tight refrigerant circuit -- Reduction of leaks as no capillary tubes and flare connec-tions are used -- Verification of pressure transducers and temperature sensors without transferring refrigerant charge -- Liquid line service valve for simplified maintenance (option) AIR TREATMENT ■■ Extremely high full load and part load energy efficiency: -- Eurovent energy efficiency class A to C. -- Standardised Eurovent values in accordance with EN 14511-3:2013: EER up to 3.2 and ESEER up to 4. -- Twin-rotor screw compressor equipped with a high-­efficiency motor and a variable capacity valve that permits exact matching of the cooling capacity to the load. -- All aluminium condenser with high-efficiency microchannels. -- Flooded shell-and-tube evaporator to increase the heat exchange efficiency. -- Electronic expansion device permitting operation at a lower condensing pressure and improved utilisation of the evaporator heat exchange surface (superheat control). -- Economizer system with electronic expansion device for increased cooling capacity Environmental care CONTROLS Very economical operation 165