AHI Carrier Catalog | Page 160

Physical data 30XAS 242 Compressors Refrigerant** No of circuits Standard unit Refrigerant charge COOLING Unit + option 254/255 Refrigerant charge Capacity control Minimum capacity Condensers Fans Standard unit and unit + option 119/254* Quantity Standard unit Maximum total air flow Max speed Standard unit + options 119* Maximum total air flow Max speed Evaporator Water content Without hydronic module Water inlet/outlet connections Nominal diameter Actual outside diameter Maximum water-side pressure† With hydronic module (option 116C) Water inlet/outlet connections Nominal diameter Actual outside diameter Expansion tank valume Maximum water-side pressure Chassis paint colour 442 482 kg 06T semi-hermetic screw compressors, 50 r/s R-134a 1 1 1 1 1 kg teqCO2 60 85.8 83 118.7 88 125.8 kg teqCO2 85 95 105 121.6 135.9 150.2 Touch Pilot, electronic expansion valve (EXV) 30 30 30 All-aluminium micro-channel heat exchanger Axial Flying Bird 4, rotating shroud 120 171.6 130 185.9 30 30 4 5 6 7 8 l/s r/s 13667 11.7 17083 11.7 20500 11.7 23917 11.7 27333 11.7 l/s r/s 27083 15.7 31597 15.7 36111 15.7 l 18055 22569 15.7 15.7 Flooded multi-pipe type 53 53 53 75 75 in mm kPa Victaulic 5 141.3 1000 5 141.3 1000 5 141.3 1000 5 141.3 1000 5 141.3 1000 Victaulic 4 114.3 50 400 Colour code: RAL7035 4 114.3 50 400 4 114.3 50 400 4 114.3 50 400 % in mm l kPa 282 342 72 103 73 104.4 † Eurovent-certified performances in accordance with standard EN14511-3:2013. Cooling mode conditions: evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C. evaporator fouling factor 0 m2 K/W †† Gross performances, not in accordance with EN14511-3:2013. These performances do not take into account the correction for the proportional heating capacity and power input generated by the water pump to overcome the internal pressure drop in the heat exchanger. Evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C. evaporator fouling factor 0 m2 K/W * Options: 119 = High energy efficiency, 257 = low noise level, 279 = compressor enclosure, 258,= very low sound level, 254 = traditional coils (Cu/Al), 255 = traditional coils (Cu/Al) without slots ** Weights are guidelines only. Refer to the unit nameplate. *** in dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. **** in dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from the sound power level Lw(A). Notes: 1 Option 119 can be used with options 254 or 255. Contact your Carrier representative for the performances. Eurovent certified data 160 C A R R I E R 2 0 1 6 / 2 0 1 7