Physical data
30XAS
242
Compressors
Refrigerant**
No of circuits
Standard unit
Refrigerant charge
COOLING
Unit + option 254/255
Refrigerant charge
Capacity control
Minimum capacity
Condensers
Fans
Standard unit and unit + option 119/254*
Quantity
Standard unit
Maximum total air flow
Max speed
Standard unit + options 119*
Maximum total air flow
Max speed
Evaporator
Water content
Without hydronic module
Water inlet/outlet connections
Nominal diameter
Actual outside diameter
Maximum water-side pressure†
With hydronic module (option 116C)
Water inlet/outlet connections
Nominal diameter
Actual outside diameter
Expansion tank valume
Maximum water-side pressure
Chassis paint colour
442
482
kg
06T semi-hermetic screw compressors, 50 r/s
R-134a
1
1
1
1
1
kg
teqCO2
60
85.8
83
118.7
88
125.8
kg
teqCO2
85
95
105
121.6
135.9
150.2
Touch Pilot, electronic expansion valve (EXV)
30
30
30
All-aluminium micro-channel heat exchanger
Axial Flying Bird 4, rotating shroud
120
171.6
130
185.9
30
30
4
5
6
7
8
l/s
r/s
13667
11.7
17083
11.7
20500
11.7
23917
11.7
27333
11.7
l/s
r/s
27083
15.7
31597
15.7
36111
15.7
l
18055
22569
15.7
15.7
Flooded multi-pipe type
53
53
53
75
75
in
mm
kPa
Victaulic
5
141.3
1000
5
141.3
1000
5
141.3
1000
5
141.3
1000
5
141.3
1000
Victaulic
4
114.3
50
400
Colour code: RAL7035
4
114.3
50
400
4
114.3
50
400
4
114.3
50
400
%
in
mm
l
kPa
282
342
72
103
73
104.4
† Eurovent-certified performances in accordance with standard EN14511-3:2013.
Cooling mode conditions: evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C. evaporator fouling factor 0 m2 K/W
†† Gross performances, not in accordance with EN14511-3:2013. These performances do not take into account the correction for the proportional heating capacity and power input
generated by the water pump to overcome the internal pressure drop in the heat exchanger. Evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C.
evaporator fouling factor
0 m2 K/W
* Options: 119 = High energy efficiency, 257 = low noise level, 279 = compressor enclosure, 258,= very low sound level, 254 = traditional coils (Cu/Al), 255 = traditional coils (Cu/Al)
without slots
** Weights are guidelines only. Refer to the unit nameplate.
*** in dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with
ISO 9614-1 and certified by Eurovent.
**** in dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from
the sound power level Lw(A).
Notes:
1
Option 119 can be used with options 254 or 255. Contact your Carrier representative for the performances.
Eurovent certified data