COOLING Options Options No. Description Unit for indoor installation with discharge ducts 12 Low noise level 15 Use 30RB Advantages Ducted condenser air discharge, optimised condensing temperature control, based on the operating conditions and system characteristics Noise emission reduction Fans with available pressure 602-802 Sound absorbing compressor enclosure Sound absorbing compressor enclosure and low-speed Very low noise level 15LS Noise emission reduction fans Metallic grilles on all four unit faces (this option Grilles 23 Improved aesthetics includes the supply of enclosure panels) Enclosure panels 23A Side panels on each end of the coils Improved aesthetics Stable unit operation when the air temperature is Winter operation down to -20°C 28 Fan speed control via frequency converter between 0°C and -20°C Stable unit operation when the air temperature is Winter operation down to -10°C 28B Twin-speed lead fan for each circuit between 0°C and -10°C Winter operation down to -10°C and Noise emission reduction and stable unit Sound absorbing compressor enclosure and lowvery low noise level (options 28B + 28C operation when the air temperature is between speed fans + twin-speed lead fan for each circuit 15LS) 0°C and -10°C Evaporator and water piping frost Electric heater on the evaporator and the water inlet/ Evaporator frost protection for air temperatures 41 protection outlet piping between 0°C and -20°C Partial heat reclaim by desuperheating of the Free high-temperature hot-water production Partial heat reclaim 49 compressor discharge gas simultaneously with chilled water production Unit equipped with an additional field-installed leaving Optimised operation of two chillers connected in Master/slave operation 58 water temperature sensor, allowing master/slave parallel with operating time equalisation operation of two chillers connected in parallel Main disconnect switch without fuse Factory-installed main electric disconnect switch in Ease-of-installation and compliance with local 70 (standard for sizes 162-262) the control box electrical regulations Factory-installed main electric disconnect switch with Same advantage as main disconnect switch and Main disconnect switch with fuse 70D fuse in the control box reinforced anti-short circuit protection Evaporator thermal insulation protection by aluminium Evaporator with aluminium jacket 88 Improved resistance to climatic aggression sheets Shut-off valve on the compressor suction piping Suction valve 92 Simplified maintenance (discharge valve as standard) Two-directional communications board, complies with Easy connection by communication bus to a JBus gateway 148B JBus protocol building management system Two-directional communications board, complies with Easy connection by communication bus to a Bacnet gateway 148C Bacnet protocol building management system Two-directional communications board, complies with Easy connection by communication bus to a LonTalk gateway 148D LonTalk protocol building management system Easy wired connection to a building management Energy Management Module EMM 156 See controls manual system Safety valve inspection and replacement Safety valve with three-way valve Three-way valve upstream of the safety valves (not 194 facilitated fitted compatible with BPHE version) without refrigerant loss Conformance with Australian 200 Heat exchanger approved to Australian code regulations Refrigerant charge stored in the condenser. Option not Unit transport by container only possible with this Unit storage above 48°C 241 compatible with MCHE coils; Cu/Al coils are required to option store the charge. Microchannel MCHE protection by the Carrier factory Better corrosion resistance, recommended for Anti-corrosion protection Enviro262 for applications in standard and moderate corrosive marine Shield for microchannel MCHE coils environments. or moderately corrosive industrial environments The Super Enviro-Shield option was developed to Anti-corrosion protection Super Microchannel MCHE protection by the Carrier increase the microchannel MCHE coil application Enviro-Shield for microchannel 263 factory for applications in corrosive and aggressive range MCHE coils environments to extremely corrosive environmental conditions. Connection sleeve 266 Piping to be welded with Victaulic connection Ease-of-installation Ensures compatibility with other options than Shell-and- tube evaporator 280 Different heat exchanger type those available with the standard unit (see Electronic Catalogue) Power cable connection side Side extension on the power control to allow a reduced 283 Use of thicker power cables extension cable bend radius Permit connection of a laptop or an electrical 230 V electrical plug 284 23