AIR-COOLED SCROLL CHILLERS WITH GREENSPEED INTELLIGENCE 30RBM/30RBP 160-520 ® Electrical data 30RBM 160 180 200 220 260 300 330 360 400 430 470 520 Power circuit Nominal power supply Voltage range Control circuit supply Nominal unit current draw* Circuits A + B Maximum unit power input** Circuits A + B Cosine phi, unit at max. capacity** Maximum unit current draw (Un-10%)*** Circuits A + B Maximum unit current draw (Un)**** Circuits A + B Maximum start-up current, standard unit (Un)† Circuits A + B Max. start-up current, unit with soft starter (Un)† Circuits A + B A 100 110 124 133 161 180 201 221 242 261 282 322 kW 80 0.88 87 0.87 98 0.87 107 0.88 129 0.88 145 0.88 161 0.88 177 0.88 193 0.88 209 0.88 225 0.88 258 0.88 A 144 158 176 192 230 259 288 317 345 374 403 460 A 133 146 163 177 212 239 266 292 319 345 372 425 A 307 356 374 352 423 450 476 503 529 556 583 636 A 261 283 300 305 349 376 403 429 456 482 509 562 COOLING V-ph-Hz 400 - 3 - 50 V 360 - 440 24 V via internal transformer * ** Standardised Eurovent conditions: Evaporator entering/leaving water temperature 12 °C/7 °C, outside air temperature 35 °C. Power input, compressors and fans, at the unit operating limits (saturated suction temperature 15 °C, saturated condensing temperature 68.3 °C) and nominal voltage of 400 V (data given on the unit nameplate). *** Maximum unit operating current at maximum unit power input and 360 V. **** Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate). † Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). 30RBP 160 180 200 220 260 300 330 360 400 430 470 520 Power circuit Nominal power supply Voltage range Control circuit supply Nominal unit current draw* Circuits A + B Maximum unit power input** Circuits A + B Cosine phi, unit at max. capacity** Maximum unit current draw (Un-10%)*** Circuits A + B Maximum unit current draw (Un)**** Circuits A + B Maximum start-up current, standard unit (Un)† Circuits A + B Max. start-up current, unit with soft starter (Un)† Circuits A + B V-ph-Hz 400 - 3 - 50 V 360 - 440 24 V via internal transformer A 97 107 121 130 158 176 197 216 237 255 276 316 kW 80 0.88 87 0.88 98 0.88 106 0.88 128 0.88 144 0.88 160 0.88 176 0.88 192 0.88 208 0.88 224 0.88 256 0.88 A 142 154 173 189 227 255 284 312 340 369 397 454 A 131 142 160 174 209 235 262 287 314 340 366 419 A 305 353 371 349 420 446 472 498 525 550 577 629 A 259 279 297 302 346 372 399 424 451 477 503 556 * ** Standardised Eurovent conditions: Evaporator entering/leaving water temperature 12 °C/7 °C, outside air temperature 35 °C. Power input, compressors and fans, at the unit operating limits (saturated suction temperature 15 °C, saturated condensing temperature 68.3 °C) and nominal voltage of 400 V (data given on the unit nameplate). *** Maximum unit operating current at maximum unit power input and 360 V. **** Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate). † Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). Fan motor electrical data upstream variable frequency drive: Units at Eurovent equivalent conditions and motor ambient air temperature of 50 °C at 400 V: 3.0 A, start-up current 20 A, power input 1.75 kW. CONTROLS HEATING HEATING Fan motor electrical data: Units at Eurovent equivalent conditions and motor ambient air temperature of 50 °C at 400 V: 3.8 A, start-up current 20 A, power input 1.75 kW. AIR TREATMENT C A R R I E R 2 0 1 6 / 2 0 1 7 133