AHI Carrier Catalog | Page 112

COOLING
Options No . Description Advantages
Corrosion protection , traditional coils
2B
Factory application of Blygold Polual
treatment on the copper / aluminium coils
Corrosion protection , traditional coils
3A
Fins made of pre-treated aluminium
( polyurethane and epoxy )
Medium-temperature brine solution
5B
Low temperature chilled water
production down to 0 ° C with ethylene
glycol and propylene glycol .
Improved corrosion resistance , recommended for industrial , rural and marine environments Improved corrosion resistance , recommended for moderate marine and urban environments Covers specific applications such as ice storage and industrial processes
Low-temperature brine solution
6B
Low temperature chilled water production
Covers specific applications such as ice
down to -15 ° C with ethylene glycol and
storage and industrial processes
-12 ° C with propylene glycol .
Very low noise level
15LS
Acoustic compressor enclosure and lowspeed
Noise emission reduction at reduces fan
fans
speed
Use 30RBSY
30RBSY 039-160
30RBSY 039-160
30RBSY 039-160
30RBSY 039-160
30RBSY
039-160
Protection grilles
23
Metallic protection grilles
Coil protection against possible shocks
30RBSY
039-160
Suction filter
23B
Washable G2 efficiency filter in accordance with EN 779
Prevents pollution of the air-heat exchanger
30RBSY 039-160
Soft Starter
25
Electronic starter on each compressor
Reduced start-up current
30RBSY 039-160
Frost protection down to -20 ° C
42
Electric heater on the hydronic module
Hydronic module frost protection at low outside temperatures
30RBSY 039-160
Partial heat recovery
49
Partial heat recovery by desuperheating of the compressor discharge gas . Note : With option 49 the units are equipped with traditional coils ( Cu / Al ).
Free high-temperature hot-water production simultaneously with chilled and hot-water production
30RBSY 039-160
Master / slave operation
58
Unit equipped with supplementary water outlet temperature sensor kit to be fieldinstalled allowing master / slave operation of two units connected in parallel
Optimised operation of two chillers connected in parallel with operating time equalisation
30RBSY 039-160
Main disconnect switch without fuse
70
Factory-installed main electric disconnect
Ease-of-installation and compliance with
30RBSY
switch in the control box
local electrical regulations
039-160
HP single-pump hydronic module
116B
Single high-pressure water pump , water filter , expansion tank , temperature and
Easy and fast installation
30RBSY 039-160
pressure sensors . See hydronic module option .
HP dual-pump hydronic module
116C
Dual high-pressure water pump , water filter , expansion tank , temperature and pressure sensors . See hydronic module option .
Easy and fast installation , operating safety
30RBSY 039-160
LP single-pump hydronic module
116F
Single low-pressure water pump , water filter , expansion tank , temperature and pressure sensors . See hydronic module option .
LP dual-pump hydronic module
116G
Dual low-pressure water pump , water
filter , expansion tank , temperature and
pressure sensors . See hydronic module
option .
HP variable-speed single-pump hydronic module
116J
Single high-pressure water pump , water filter , expansion tank , temperature and pressure sensors . See hydronic module option .
Easy and fast installation
Easy and fast installation , operating safety
Easy and fast installation , reduced power consumption of the water circulation pump
30RBSY 039-160
30RBSY 039-160
30RBSY 039-160
112 C A R R I E R 2 0 1 6 / 2 0 1 7