DUCTABLE AIR-COOLED LIQUID CHILLERS  30RBSY 039-160 Physical data 30RBSY 039 045 050 060 070 080 090 100 120 140 160 Outside diameter mm 60.3 60.3 Colour code: RAL7035 Chassis paint colour 60.3 60.3 60.3 60.3 60.3 60.3 60.3 60.3 HEATING HEATING AIR TREATMENT Air conditioning application as per EN14511-3:2013† - standard unit Condition 1: Nominal cooling capacity kW 39.6 44.0 51.2 58.1 66.2 77.7 86.7 97.1 114.4 132.8 153.4 ESEER kW/ kW 3.81 3.95 3.94 3.85 3.68 3.68 3.82 3.87 3.83 3.74 3.88 EER kW/ kW 2.87 2.76 2.65 2.67 2.65 2.61 2.69 2.70 2.65 2.63 2.56 Eurovent class cooling A B B B B B B B B B B Condition 2: Nominal cooling capacity kW 53.0 58.9 68.5 80.8 83.6 97.0 114.3 126.5 150.8 168.9 191.7 EER kW/ kW 3.44 3.33 3.11 3.32 2.89 2.96 3.13 3.06 3.09 2.91 2.91 Air conditioning application†† - standard unit Condition 1: Nominal cooling capacity kW 39.9 44.4 51.6 58.6 66.8 78.4 87.2 97.7 115.1 133.6 154.4 ESEER kW/ kW 3.28 3.46 3.56 3.54 3.31 3.39 3.26 3.35 3.41 3.40 3.61 2.58 2.56 2.52 2.48 EER kW/ kW 2.69 2.63 2.56 2.59 2.55 2.54 2.55 Condition 2: Nominal cooling capacity kW 53.5 59.4 69.3 81.7 84.3 97.9 115.3 127.4 152.1 170.3 193.4 EER kW/ kW 3.31 3.23 3.06 3.29 2.82 2.92 3.02 2.97 3.03 2.83 2.86 Sound levels Standard unit - for 160 Pa external static pressure Sound power level at discharge* dB(A) 84 84 84 84 87 87 87 87 87 90 90 Sound power level radiated* dB(A) 84 84 84 84 87 87 87 87 87 90 90 Sound pressure level at 10 m** dB(A) 53 53 53 53 55 55 56 56 56 58 58 Dimensions If two values are shown the first one is for standard units and the second one for units with option 23B Length mm 2142/ 2142/ 2142/ 2142/ 2142/ 2142/ 2273 2273 2273 2273 2273 2307 2307 2307 2307 2307 2307 Width mm 1132/ 1132/ 1132/ 1132/ 1132/ 1132/ 2122 2122 2122 2122 2122 1297 1297 1297 1297 1297 1297 Height mm 1371 1371 1371 1371 1371 1371 1371 1371 1371 1371 1371 Operating weight with MCHE coil*** 771 780 793 901 932 Standard unit without hydronic module kg 436 443 449 464 461 480 Standard unit with hydronic module Single high-pressure pump kg 466 473 479 494 491 510 803 812 829 940 971 Dual high-pressure pump kg 491 499 504 520 517 536 848 857 877 977 1008 Compressors Hermetic scroll compressors, 48.3 r/s Circuit A 2 2 2 2 2 2 3 3 3 2 2 Circuit B 2 2 No of control stages 2 2 2 2 2 2 3 3 3 4 4 Refrigerant charge with MCHE coil*** R-410A C ircuit A kg 4.7 4.5 6.3 6.7 6.2 7.3 9.5 10.8 11.4 6.3 8 Circuit B kg 6.3 8 Capacity control Touch Pilot Junior Minimum capacity % 50 50 50 50 50 50 33 33 33 25 25 Condensers All-aluminium microchannel heat exchanger (MCHE) Fans Axial Flying Bird IV with rotating shroud Quantity 1 1 1 1 1 1 2 2 2 2 2 3908 4982 5267 6940 6936 7370 9958 10534 Maximum total air flow l/s 3885 3883 3687 Maximum rotation speed r/s 16 16 16 18 18 18 16 16 16 16 16 Evaporator Direct expansion. plate heat exchanger Water volume l 2.6 3.0 3.3 4.0 4.8 5.6 8.7 9.9 11.3 12.4 14.7 Without hydronic module (option) Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 without hydronic module With hydronic module (option) Single or dual pump (as selected) Pump, Victaulic screen filter, safety valve, expansion tank, purge valves (water + air), pressure sensors Expansion tank volume l 12 12 12 12 12 12 35 35 35 35 35 Expansion tank pressure**** bar 1 1 1 1 1 1 1.5 1.5 1.5 1.5 1.5 Max. water-side operating pressure kPa 400 400 400 400 400 400 400 400 400 400 400 Water connections with/without hydronic module Victaulic Diameter in 2 2 2 2 2 2 2 2 2 2 2 COOLING Cooling 60.3 † Eurovent-certified performances in accordance with standard EN14511-3:2013. †† Gross performances, not in accordance with EN14511-3:2013. These performances do not take into account the correction for the proportionnal heating capacity and power input generated by the water pump to overcome the internal pressure drop in the heat exchanger. Condition 1: cooling mode conditions: evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C, evaporator fooling factor 0 m².K/W Condition 2: cooling mode conditions: evaporator water entering/leaving temperature 23°C/18°C, outside air temperature 35°C, evaporator fooling factor 0 m².K/W * In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. ** In dB ref 20μPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from the sound power level Lw(A). *** Weight shown is a guideline only. Please refer to the unit nameplate. **** When delivered, the standard pre-inflation of the tank is not necessarily the optimal value for the system. To permit changing the water volume, change the inflation pressure to a pressure that is close to the static head of the system. Fill the system with water (purging the air) to a pressure value that is 10 to 20 kPa higher than the pressure in the tank Eurovent certified data C A R R I E R 2 0 1 6 / 2 0 1 7 109 CONTROLS