AHI Carrier Catalog | Page 97

AIR-COOLED LIQUID CHILLERS 30RBS 039-160 Advantages Use 30RBS Easy and fast installation 30RBS 039-160 Easy and fast installation, operating safety 30RBS 039-160 Easy and fast installation, reduced power consumption of the water circulation pump Easy and fast installation, operating safety, reduced power consumption of the water circulation pump Easy and fast installation 30RBS 039-160 Easy and fast installation, operating safety 30RBS 039-160 Easy and fast installation 30RBS 039-160 Easy and fast installation, operating safety 30RBS 039-160 Easy and fast installation, reduced power consumption of the water circulation pump Easy and fast installation, operating safety, reduced power consumption of the water circulation pump Easy connection by communication bus to a building management system Easy connection by communication bus to a building management system Easy connection by communication bus to a building management system Improved corrosion resistance, recommended for moderately corrosive marine and industrial environments. 30RBS 039-160 LP dual-pump hydronic module 116U High-pressure variable-speed single-pump hydronic module 116V HP variable-speed dual-pump hydronic module 116W JBus gateway 148B Bacnet gateway 148C LonTalk gateway 148D Enviro-Shield anti-corrosion protection 262 Super Enviro-Shield anticorrosion protection 263 Water heat exchanger screw connection sleeves Welded evaporator water connection kit 264 Single low-pressure water pump, water filter, expansion tank, temperature and pressure sensors. See hydronic module option. Dual low-pressure water pump, water filter, expansion tank, temperature and pressure sensors. See hydronic module option. Single high-pressure water pump, water filter, expansion tank, temperature and pressure sensors. See hydronic module option. Dual high-pressure water pump, water filter, expansion tank, temperature and pressure sensors. See hydronic module option. Single high-pressure water pump, water filter, temperature and pressure sensors. See hydronic module option. Dual high-pressure water pump, water filter, temperature and pressure sensors. See hydronic module option. Single low-pressure water pump, water filter, temperature and pressure sensors. See hydronic module option. Dual low-pressure water pump, water filter, temperature and pressure sensors. See hydronic module option. Single high-pressure water pump, water filter, temperature and pressure sensors. See hydronic module option. Dual high-pressure water pump, water filter, temperature and pressure sensors. See hydronic module option. Two-directional communications board, complies with JBus protocol Two-directional communications board, complies with Bacnet protocol Two-directional communications board, complies with Lon Talk protocol Coating by conversion process which modifies the surface of the aluminum producing a coating that is integral to the coil. Complete immersion in a bath to ensure 100% coverage. No heat transfer variation, tested 4000 hours salt spray per ASTM B117 Extremely durable and flexible epoxy polymer coating applied on micro channel heat exchangers by electro coating process, final UV protective topcoat. Minimal heat transfer variation, tested 6000 hours constant neutral salt spray per ASTM B117, superior impact resistance per ASTM D2794 Inlet/outlet screw connection sleeves 266 Victaulic piping connections with welded joints Reinforced ECM filtration for fan VFD*** 282A Fan variable frequency drive compliance to IEC 61800-3  C1 class Reinforced ECM filtration for pump VFD**** 282B Pump variable frequency drive compliance to IEC 61800-3  C1 class LP dual-pump hydronic module 116G HP variable-speed single-pump hydronic module 116J HP variable-speed dual-pump hydronic module 116K HP single-pump hydronic module without expansion tank 116R HP dual-pump hydronic module without expansion tank 116S LP single-pump hydronic module 116T 30RBS 039-160 COOLING LP single-pump hydronic module 116F Description 30RBS 039-160 30RBS 039-160 HEATING HEATING No. 30RBS 039-160 30RBS 039-160 30RBS 039-160 30RBS 039-160 The Super Enviro-Shield option was 30RBS 039-160 developed to extend the application range of MCHE heat exchangers in very corrosive environmental conditions. Permit connection of the unit to a screw connection Permit connection of the unit to a connection other than a Victaulic connection Allows unit installation in domestic residential environment by reducing electromagnetic interferences Allows unit installation in domestic residential environment by reducing electromagnetic interferences AIR TREATMENT Options 30RBS 039-160 30RBS 039-160 30RBS 039-160 30RBS 039-160 CONTROLS *** 30RBS 039-160 with option 5B or 6B or 28 **** 30RBS 039-160 with option 116 J or K or V or W C A R R I E R 2 0 1 6 / 2 0 1 7 97