AIR-COOLED LIQUID CHILLERS 30RBS 039-160
Physical data
30RBS
039
045
050
060
070
080
090
100
120
140
160
HEATING HEATING
AIR TREATMENT
Air conditioning application as per EN14511-3:2013† - standard unit
Condition 1:
Nominal cooling capacity
kW
40
44
51
58
67
79
87
97
114
135
156
ESEER
kW/ kW
3.75
3.88
3.95
3.80
3.62
3.67
3.91
3.94
3.83
3.68
3.87
EER
kW/ kW
2.87
2.76
2.67
2.66
2.72
2.70
2.73
2.73
2.67
2.70
2.65
Eurovent class cooling
C
C
D
D
C
C
C
C
D
C
D
Condition 2:
Nominal cooling capacity
kW
53
59
69
81
85
98
114
126
151
171
194
EER
kW/ kW
3.44
3.32
3.12
3.31
2.97
3.06
3.18
3.09
3.10
2.99
3.01
††
Air conditioning application - standard unit
Condition 1:
Nominal cooling capacity
kW
40
44
52
59
68
80
87
98
115
136
157
ESEER
kW/ kW
3.97
4.14
4.22
4.06
3.84
3.90
4.16
4.18
4.08
3.94
4.16
2.79
2.73
2.77
2.72
EER
kW/ kW
2.95
2.84
2.75
2.74
2.80
2.78
2.79
Condition 2:
Nominal cooling capacity
kW
54
59
69
82
86
99
115
127
152
173
196
EER
kW/ kW
3.59
3.47
3.26
3.47
3.08
3.19
3.28
3.19
3.21
3.09
3.12
Sound levels
Standard unit
Sound power level*
dB(A)
80
81
81
81
87
87
84
84
84
90
90
Sound pressure level at 10 m**
dB(A)
49
49
49
49
55
55
52
52
52
58
58
Unit with option 15LS
Sound power level*
dB(A)
79
80
80
80
80
80
83
83
83
83
83
Sound pressure level at 10 m**
dB(A)
48
48
48
48
48
48
51
51
51
51
51
Dimensions
Length
mm
1061
1061
1061
1061
1061
1061
2258
2258
2258
2258
2258
Width
mm
2050
2050
2050
2050
2050
2050
2050
2050
2050
2050
2050
Height
mm
1330
1330
1330
1330
1330
1330
1330
1330
1330
1330
1330
Operating weight with MCHE coil***
454
471
766
776
789
896
928
Standard unit without hydronic
kg
429
436
442
454
module
Standard unit with hydronic module
Single high-pressure pump
kg
459
466
472
484
484
501
798
808
825
935
967
Dual high-pressure pump
kg
484
492
497
510
510
527
843
853
873
972
1004
Compressors
Hermetic scroll compressors, 48.3 r/s
Circuit A
2
2
2
2
2
2
3
3
3
2
2
Circuit B
2
2
Number of capacity stages
2
2
2
2
2
2
3
3
3
4
4
Refrigerant charge with MCHE coil***
R-410A
Circuit A
kg
4.7
5.3
5.9
6.7
6.2
7.3
10.7
10.8
11.4
6.5
7.4
Circuit B
kg
6.5
7.4
Capacity control
Touch Pilot Junior
Minimum capacity
%
50
50
50
50
50
50
33
33
33
25
25
Condensers
All-aluminium microchannel heat exchanger (MCHE)
Fans
Axial Flying Bird IV with rotating shroud
Quantity
1
1
1
1
1
1
2
2
2
2
2
3883
3687
3908
5013
5278
6940
6936
7370
10026 10556
Maximum total air flow
l/s
3885
Maximum rotation speed
r/s
12
12
12
12
16
16
12
12
12
16
16
Evaporator
Direct expansion. plate heat exchanger
Water volume
l
2.6
3.0
3.3
4.0
4.8
5.6
8.7
9.9
11.3
12.4
14.7
Without hydronic module
Max. water-side operating pressure
kPa
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
With hydronic module (option)
Single or dual pump (as selected)
Pump, Victaulic screen filter, safety valve, expansion tank, purge valves (water + air), pressure sensors
Expansion tank volume
l
12
12
12
12
12
12
35
35
35
35
35
Expansion tank pressure****
bar
1
1
1
1
1
1
1.5
1.5
1.5
1.5
1.5
Max. water-side operating pressure
kPa
400
400
400
400
400
400
400
400
400
400
400
Water connections with/without hydronic module Victaulic
Diameter
in
2
2
2
2
2
2
2
2
2
2
2
Outside diameter
mm
60.3
60.3
60.3
60.3
60.3
60.3
60.3
60.3
60.3
60.3
60.3
Colour code: RAL7035
Chassis paint colour
COOLING
Cooling
†
Eurovent-certified performances in accordance with standard EN14511-3:2013.
†† Gross performances, not in accordance with EN14511-3:2013. These performances do not take into account the correction for the proportionnal heating capacity and power input
generated by the water pump to overcome the internal pressure drop in the heat exchanger.
Condition 1: cooling mode conditions: evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C, evaporator fooling factor 0 m².K/W
Condition 2: cooling mode conditions: evaporator water entering/leaving temperature 23°C/18°C, outside air temperature 35°C, evaporator fooling factor 0 m².K/W
* In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with
ISO 9614-1 and certified by Eurovent.
** In dB ref 20μPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from
the sound power level Lw(A).
*** Weight shown is a guideline only. Please refer to the unit nameplate.
**** When delivered, the standard pre-inflation of the tank is not necessarily the optimal value for the system. To permit changing the water volume, change the inflation pressure to a
pressure that is close to the static head of the system. Fill the system with water (purging the air) to a pressure value that is 10 to 20 kPa higher than the pressure in the tank.
Eurovent certified data
C
A
R
R
I
E
R
2
0
1
6
/
2
0
1
7
95