AHI Carrier Catalog | Page 809

SPLIT-SYSTEM UNITS  38NZ/NF & 40NZ/NF Outdoor unit 38NZ/NF The 38NZNF unit can incorporate a return air filter Centrifugal fans or plug-fans (optional) Operation during “all seasons” via the condensation pressure control by damper Indoor unit 40NZ/NF Indoor air quality using different combinations of gravimetric and opacimetric filters MFVA module Free-cooling module (optional) with built-in plug-fan and posibility of cooling recovery circuit Unit components Outdoor unit 38NZ/NF ■■ Outdoor air circuit -- Centrifugal fan coupling by pulleys and belts. Electric motor(s) with tensioner, class F, IP55 and internal thermal protection. One double-intake turbine, with an impeller with front-curved blades. Greased spherical bearings, with no maintenance required. -- Coil(s) with copper pipes and aluminium fins. -- Condensates drain pan. ■■ Cooling circuit -- Hermetic scroll-type compressor(s), assembled over antivibration mounts. Control of phase equilibrium and the direction of rotation. -- Crankcase heater. -- Therm ostatic expansion valve with external equalisation (heat pump units). -- Four-way cycle reversing valves (heat pump units). -- Particle separator(s), anti-acid dehydrating filter(s), liquid receiver(s). -- Cooling connections for welding. -- Maximum equivalent length of the cooling line 50 metres (for longer distances an oil separator must be used). ■■ Electric panel -- Complete and fully wired electric panel. Insulated panel cover to prevent condensation. Protection IP55. -- Transformer for power supply without neutral included in the electrical panel. -- Main ground connection. -- Compressor(s) and fan(s) motor contacts. AIR TREATMENT -- C asing made of galvanised steel metal with polyester paint, white colour RAL 7035. Self-supporting frame. ■■ Protections -- High and low pressure pressostats. -- Compressor discharge temperature control. -- Non-return valve built into the compressor. -- Main door switch. -- Magnetothermic protection switches for the compressor(s) power line and fans motor. -- Automatic switch in the control circuit. Indoor unit 40NZ/NF ■■ Indoor air circuit -- Coil with copper pipes and aluminium fins. -- Centrifugal fan(s) coupling by pulleys and belts. Electric motor(s) with tensioner, class F, IP55 and internal thermal protection. Double-intake turbines, with an impeller of front-curved blades. Greased spherical bearings, with no maintenance required. C A R R I E R 2 0 1 6 / 2 0 1 7 -- Reusable air filters, assembled on a frame. -- Condensate drain pan. ■■ Cooling circuit -- Thermostatic expansion valve(s) with external equalisation (check valve in 40NF series). CONTROLS -- Casing made of galvanised steel metal with polyester paint, white colour RAL 7035. Self-supporting frame. ■■ Protections -- Main door switch. 809