AHI Carrier Catalog | Page 250

Standard-efficiency units Standard-efficiency units 30XW-- 852 1002 1052 1154 1252 1352 1452 1552 1652 1702 Cooling Air conditioning application as per EN14511-3:2013† - standard unit COOLING Condition 1 Nominal cooling capacity kW 839 1017 1060 1141 1257 1342 1453 1547 1654 1728 ESEER kW/kW 5.94 6.30 6.34 6.23 6.73 6.44 6.27 6.06 6.40 6.34 EER kW/kW 5.39 5.26 5.21 5.30 5.69 5.51 5.36 5.29 5.59 5.60 Eurovent class cooling - A A A A A A A - - - Air conditioning application †† - standard unit Condition 1 Nominal cooling capacity kW 843 1021 1066 1146 1262 1349 1461 1557 1664 1739 ESEER kW/kW 6.65 7.36 7.56 7.49 7.69 7.46 7.42 7.29 7.58 7.59 EER kW/kW 5.66 5.56 5.53 5.64 5.97 5.82 5.71 5.67 5.96 6.00 Sound power level* dB(A) 99 102 102 102 102 102 102 102 102 102 Sound pressure level at 1 m** dB(A) 82 84 84 84 83 83 83 83 83 83 Sound levels - standard unit Sound levels - standard unit + option 257*** Sound power level* dB(A) 96 99 99 99 99 99 99 99 99 99 Sound pressure level at 1 m** dB(A) 78 80 80 80 80 80 80 80 80 80 Length mm 2780 4025 4025 4025 4730 4730 4730 4730 4790 4790 Width mm 1042 1036 1036 1036 1156 1156 1156 1156 1902 1902 Height mm 1898 1870 1870 1925 2051 2051 2051 2051 1515 1515 Operating weight**** kg 3492 5370 5408 5698 7066 7267 7305 7337 8681 8699 Circuit A - 1 1 1 1 1 1 1 1 1 1 Circuit B - - 1 1 1 1 1 1 1 1 1 Circuit A kg 140 85 85 105 120 115 110 105 195 195 Circuit B kg - 85 85 105 120 115 110 105 195 195 tonnes 200 122 122 150 172 164 157 150 279 279 % 15 10 10 10 10 10 10 10 10 10 Water volume l 98 182 182 205 301 301 301 301 354 354 Water connections (Victaulic) in 6 6 6 8 8 8 8 8 8 8 Drain and vent connections (NPT) in 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Water volume l 137 193 193 193 340 340 340 340 426 426 Water connections (Victaulic) in 8 8 8 8 8 8 8 8 8 8 Drain and vent connections (NPT) in 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Dimensions - standard unit Compressors Refrigerant**** - standard unit Global Warming Potential (GWP) Tonnes of equivalent CO2 of greatest circuit Capacity control Minimum capcity Evaporator Condenser † Eurovent-certified performances in accordance with standard EN14511-3:2013. † † Gross performances, not in accordance with EN14511-3:2013. These performances do not take into account the correction for the proportional heating capacity and power input generated by the water pump to overcome the internal pressure drop in the heat exchanger. Condition 1 : Cooling mode conditions, evaporator water entering/leaving temperature 12°C/7°C, condenser water entering/leaving temperature 30°C/35°C, evaporator fouling factor 0 m².K/W. Condition 2: Cooling mode conditions, condenser water entering/leaving temperature 40°C/45°C, evaporator water entering/leaving temperature 10°C/7°C, evaporator fouling factor 0 m².K/W. * In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. ** In dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from the sound power level Lw(A). *** Option 257 = Low noise level. **** Weight shown is guideline only. Please refer to the unit nameplate. Eurovent certified data 250 C A R R I E R 2 0 1 6 / 2 0 1 7