AHI Carrier Catalog | Page 250
Standard-efficiency units
Standard-efficiency units 30XW--
852
1002
1052
1154
1252
1352
1452
1552
1652
1702
Cooling
Air conditioning application as per EN14511-3:2013† - standard unit
COOLING
Condition 1
Nominal cooling capacity
kW
839
1017
1060
1141
1257
1342
1453
1547
1654
1728
ESEER
kW/kW
5.94
6.30
6.34
6.23
6.73
6.44
6.27
6.06
6.40
6.34
EER
kW/kW
5.39
5.26
5.21
5.30
5.69
5.51
5.36
5.29
5.59
5.60
Eurovent class cooling
-
A
A
A
A
A
A
A
-
-
-
Air conditioning application †† - standard unit
Condition 1
Nominal cooling capacity
kW
843
1021
1066
1146
1262
1349
1461
1557
1664
1739
ESEER
kW/kW
6.65
7.36
7.56
7.49
7.69
7.46
7.42
7.29
7.58
7.59
EER
kW/kW
5.66
5.56
5.53
5.64
5.97
5.82
5.71
5.67
5.96
6.00
Sound power level*
dB(A)
99
102
102
102
102
102
102
102
102
102
Sound pressure level at 1 m**
dB(A)
82
84
84
84
83
83
83
83
83
83
Sound levels - standard unit
Sound levels - standard unit + option 257***
Sound power level*
dB(A)
96
99
99
99
99
99
99
99
99
99
Sound pressure level at 1 m**
dB(A)
78
80
80
80
80
80
80
80
80
80
Length
mm
2780
4025
4025
4025
4730
4730
4730
4730
4790
4790
Width
mm
1042
1036
1036
1036
1156
1156
1156
1156
1902
1902
Height
mm
1898
1870
1870
1925
2051
2051
2051
2051
1515
1515
Operating weight****
kg
3492
5370
5408
5698
7066
7267
7305
7337
8681
8699
Circuit A
-
1
1
1
1
1
1
1
1
1
1
Circuit B
-
-
1
1
1
1
1
1
1
1
1
Circuit A
kg
140
85
85
105
120
115
110
105
195
195
Circuit B
kg
-
85
85
105
120
115
110
105
195
195
tonnes
200
122
122
150
172
164
157
150
279
279
%
15
10
10
10
10
10
10
10
10
10
Water volume
l
98
182
182
205
301
301
301
301
354
354
Water connections (Victaulic)
in
6
6
6
8
8
8
8
8
8
8
Drain and vent connections (NPT)
in
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
Max. water-side operating pressure
kPa
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
Water volume
l
137
193
193
193
340
340
340
340
426
426
Water connections (Victaulic)
in
8
8
8
8
8
8
8
8
8
8
Drain and vent connections (NPT)
in
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
Max. water-side operating pressure
kPa
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
Dimensions - standard unit
Compressors
Refrigerant**** - standard unit
Global Warming Potential (GWP)
Tonnes of equivalent CO2 of greatest
circuit
Capacity control
Minimum capcity
Evaporator
Condenser
†
Eurovent-certified performances in accordance with standard EN14511-3:2013.
† † Gross performances, not in accordance with EN14511-3:2013. These performances do not take into account the correction for the proportional heating capacity and power input
generated by the water pump to overcome the internal pressure drop in the heat exchanger.
Condition 1 : Cooling mode conditions, evaporator water entering/leaving temperature 12°C/7°C, condenser water entering/leaving temperature 30°C/35°C, evaporator fouling factor 0 m².K/W.
Condition 2: Cooling mode conditions, condenser water entering/leaving temperature 40°C/45°C, evaporator water entering/leaving temperature 10°C/7°C, evaporator fouling factor 0 m².K/W.
*
In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with
ISO 9614-1 and certified by Eurovent.
** In dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from
the sound power level Lw(A).
*** Option 257 = Low noise level.
**** Weight shown is guideline only. Please refer to the unit nameplate.
Eurovent certified data