AHI Carrier Catalog | Page 205

AIR-COOLED LIQUID CHILLERS  30XAV 500-1150 Controls ■■ Energy management: -- Internal time schedule clock controls chiller on/off times and operation at a second set-point -- The DCT (Data Collection Tool) records the alarms history to simplify and facilitate service operations. Touch Pilot control Operating range Standard Unit 30XAV 500-1150 Notes: 50 - - Legend 30 20 10  or start-ups with air temperature below -5 °C, the machine must be equipped with F option 41A. 0 -10 -20 2 4 6 8 10 12 14 Part load > 50% Part load < 50% Full load 16 Evaporator leaving water temperature, °C C A HEATING HEATING Operating range of standard unit 30XAV  elow 0 °C air temperature the unit must either be equipped with the evaporator B frost protection option 41A, or the water loop must be protected against frost by using a frost protection solution (by the installer). R R I E R 2 0 1 6 / 2 0 1 7 205 CONTROLS Entering air temperature, °C 40 Evaporator ∆T = 5K. These ranges are given by way of indication. Verify the operating range from the Carrier electronic catalogue. AIR TREATMENT ■■ New innovative smart control features: -- An intuitive and user-friendly, coloured, 7" interface -- Direct access to the unit’s technical drawings and the main service documents -- Screen-shots with concise and clear information in local languages -- Complete menu, customised for different users (end user, service personnel and Carrier-factory technicians) -- Easy access to the controller box with inclined touch screen mounting to ensure legibility under any lighting conditions -- Safe operation and unit setting: Password protection ensures that unauthorised people cannot modify any advanced parameters -- Simple and “smart” intelligence uses data collection from the constant monitoring of all machine parameters to optimise unit operation -- Night-mode: Cooling capacity management for reduced noise level. ■■ U nits with Touch Pilot control can be easily accessed from the internet, using a PC with an Ethernet connection. This makes remote control quick and easy and offers significant advantages for service operations. ■■ AquaForce with Greenspeed® Intelligence is equipped with an RS485 serial port that offers multiple remote control, monitoring and diagnostic possibilities. When networked with other Carrier equipment through the CCN (Carrier Comfort Network - proprietary protocol), all components form a HVAC system fully-integrated and balanced through one of the Carrier’s network system products, like the Chiller System Manager or the Plant System Manager (optional). ■■ The 30XAV also communicates with other building management systems via optional communication gateways. ■■ The following commands/visualisations are possible from remote connection: -- Start/Stop of the machine -- Dual set-point management: Through a dedicated contact is possible to activate a second set-point (example, unoccupied mode) -- Demand limit setting: To limit the maximum chiller capacity to a predefined value -- Water pump control: These outputs control the contactors of one/two evaporator water pumps. -- Water pumps on reversal (only with options 116S/116U): These contacts are used to detect a water pump operation fault and automatically change over to the other pump. -- Operation visualisation: Indication if the unit is operating or if it is in stand-by (no cooling load) -- Alarm visualisation. COOLING Remote management (standard)