AHI Carrier Catalog | Page 163

AIR-COOLED LIQUID CHILLERS 30XAS 242-482 No. Description Advantages Use 30XAS Compressor enclousure 279 Compressor sound enclosure 30XAS 242-482 Evaporator with aluminium jacket 230 V electrical plug 281 4 to 10 dB(A) quiter than standard unit. Refer to the physical data table for detailed values Improved resistance to aggressive climate conditions Carrier Connect link (BSS regions only) 298 Evaporator covered with an aluminium sheet for thermal insulation protection 230 V AC power supply source provided with plug socket Permits connection of a laptop or an electrical device and transformer (180 VA, 0,8 Amps) during unit commissioning or servicing 3G router board Enabler for Carrier Connect service offer Note 1: Require option 149 Note 2: When more than one machine is installed on site, only one of them shall be equipped with option 298, while all of them must be equipped with option 149 Note 3: If a Carrier® PlantCTRL™ is on site, option 298 shall be integrated in the Carrier® PlantCTRL™ while option 149 is still mandatory for each single unit. 30XAS 242-482 COOLING 30XAS 242-482 Fan with available pressure (option 10) This option allows a duct connection at the discharge side of the condenser fan. The unit is supplied with axial fans with a speed of 15.8 r/s (option 119), each equipped with a duct connection frame. The chiller can operate up to 60 Pa with reduced performance. Selection example Example 30XAS 282 with 40 Pa pressure drop Values for option 119 at the following conditions: 35°C outside air temperature 12/7°C entering/leaving water temperature The base capacities are those of option 119. To obtain capacities at various pressure drops use the correction factors in the table opposite. 30XAS options 119 + 10 Sizes 282-482 Fan pressure drop, Pa 0 20 40 Correction factor 1 -3.5 -7.5 0 -0.5 -1.0 0 -1.5 -3.5 60 0 +3.5 % l/s % kW % kW/ kW % kW Power input +1.0 +2.5 40 Pa Air flow l/s 22569 -7.5 Cooling capacity kW 280 -1 EER kW/kW 3.17 -3.5 Selection at Eurovent conditions Air flow Cooling capacity EER 0 Pa Correction factor, % 30XAS 282 Power input kW 88 20876 277 3,06 +3.5 90 -12.1 -1.5 -5.0 Total heat reclaim (option 50) Suitable for heating, domestic hot water preparation, agriculture and food industry, industrial processes and other hot-water requirements. Condenser water temperature Minimum Maximum (°C) With the total heat reclaim option it is possible to reduce the energy consumption bill considerably compared to conventional heating equipment such as fossil fuel boilers or electric water tanks. Evaporator water temperature Minimum Maximum (°C) If hot water production is required, the compressor discharge gases are directed towards the heat reclaim condenser. The refrigerant releases its heat to the hot water that leaves the condenser at a temperature of up to 60°C. In this way 100% of the heat rejected by the liquid chiller can be used to produce hot water. When the demand for heat is satisfied, the hot gas is again directed towards the air condenser where the heat is rejected to the outside air by the fans. Hot water temperature control is ensured by the chiller Pro-Dialog+ control. Entering temperature at start-up Entering temperature during operation Leaving temperature during operation 12.5* 20 25 6.8 3.3 55 55 60 45 21 15 * The entering water temperature at start-up must not fall below 12.5°C. For installations with a lower temperature a three-way valve must be used. Note: If the evaporator leaving water temperature is below 4°C, a glycol-water solution or the frost protection option must be used. CONTROLS Operating principle Entering temperature at start-up Entering temperature during operation Leaving temperature during operation Note: Heat reclaim is only possible, if the unit produces cold water at the same time. C A R R I E R 2 0 1 6 / 2 0 1 7 HEATING HEATING 284 30XAS 242-482 AIR TREATMENT Options 163