HP variable-speed dual-pump
hydronic module
116K Dual high-pressure water pump, water
filter, expansion tank, temperature and
pressure sensors. See hydronic module
option.
HP single-pump hydronic module
116R Single high-pressure water pump, water
filter, electronic water flow control,
pressure transducers. See hydronic
module option chapter
HP dual-pump hydronic module
116S Dual high-pressure water pump, water
filter, electronic water flow control,
pressure transducers. See hydronic
module option chapter
LP single-pump hydronic module
116T Single low-pressure water pump, water
filter, electronic water flow control,
pressure transducers. See hydronic
module option chapter
LP dual-pump hydronic module
116U Dual low-pressure water pump, water
filter, electronic water flow control,
pressure transducers. See hydronic
module option chapter
HP variable-speed single-pump
116V Single high-pressure water pump with
hydr onic mod.
variable speed drive (VSD), water filter,
electronic water flow control, pressure
transducers. Multiple possibilities of
water flow control. See hydronic module
option chapter
HP variable-speed dual-pump
116W Dual high-pressure water pump with
hydronic mod.
variable speed drive (VSD), water
filter, electronic flow switch, pressure
transducers. Multiple possibilities of
water flow control. See hydronic module
option chapter
J-Bus gateway
148B Two-directional communication board
complying with JBus protocol
BacNet gateway
148C Two-directional communication board
complying with BacNet protocol
Lon gateway
148D Two-directional communication board
complying with Lon Talk protocol
Enviro-Shield anti-corrosion
262
Coating by conversion process which
protection
modifies the surface of the aluminum
producing a coating that is integral to the
coil. Complete immersion in a bath to
ensure 100% coverage. No heat transfer
variation, tested 4000 hours salt spray
per ASTM B117
Super Enviro-Shield anti-corrosion
263
Extremely durable and flexible epoxy
protection
polymer coating applied on micro
channel heat exchangers by electro
coating process, final UV protective
topcoat. Minimal heat transfer variation,
tested 6000 hours constant neutral salt
spray per ASTM B117, superior impact
resistance per ASTM D2794
Evaporator screw connection sleeves 264
Evaporator inlet/outlet screw connection
sleeves
Welded evaporator water connection 266
Victaulic piping connections with welded
kit
joints
Reinforced ECM filtration for fan VFD 282A Fan variable frequency drive compliance
to IEC 61800-3 C1 class
Reinforced ECM filtration for pump
VFD
282B Pump variable frequency drive
compliance to IEC 61800-3 C1 class
Power cable connection side
extension
283
C
A
R
R
I
E
R
2
0
1
6
/
Side extension on the power control to
allow a reduced cable bend radius
2
0
1
7
Advantages
Use
30RBSY
Easy and fast installation, operating
safety, reduced power consumption of
the water circulation pump
30RBSY
039-160
Easy and fast installation (plug & play)
30RBSY
039-160
Easy and fast installation (plug & play)
30RBSY
039-160
Easy and fast installation (plug & play)
30RBSY
039-160
Easy and fast installation (plug & play)
30RBSY
039-160
Easy and fast installation (plug & play),
30RBSY
significant pumping energy cost savings 039-160
(more than two-thirds), tighter water flow
control, improved sytem reliability
Easy and fast installation (plug & play),
30RBSY
significant pumping energy cost savings 039-160
(more than two-thirds), tighter water flow
control, improved sytem reliability
Connects the unit by communication bus
to a building management system
Easy connection by communication bus
to a building management system
Connects the unit by communication bus
to a building management system
Improved corrosion resistance,
recommended for use in moderately
corrosive environments
30RBSY
039-160
30RBSY
039-160
30RBSY
039-160
30RBSY
039-160
Improved corrosion resistance,
recommended for use in extremely
corrosive environments
30RBSY
039-160
Allows unit connection to a screw
connector
Easy installation
30RBSY
039-160
30RBSY
039-160
30RBSY
039-160
Allows unit installation in domestic
residential environment by reducing
electromagnetic interferences
Allows unit installation in domestic
residential environment by reducing
electromagnetic interferences
Use of thicker power cables
30RBSY
039-160
30RBSY
039-160
111
HEATING HEATING
No.
AIR TREATMENT
Options
CONTROLS
Options
COOLING
DUCTABLE AIR-COOLED LIQUID CHILLERS
30RBSY 039-160