AHI Carrier Catalog | Page 111

Description HP variable-speed dual-pump hydronic module 116K Dual high-pressure water pump, water filter, expansion tank, temperature and pressure sensors. See hydronic module option. HP single-pump hydronic module 116R Single high-pressure water pump, water filter, electronic water flow control, pressure transducers. See hydronic module option chapter HP dual-pump hydronic module 116S Dual high-pressure water pump, water filter, electronic water flow control, pressure transducers. See hydronic module option chapter LP single-pump hydronic module 116T Single low-pressure water pump, water filter, electronic water flow control, pressure transducers. See hydronic module option chapter LP dual-pump hydronic module 116U Dual low-pressure water pump, water filter, electronic water flow control, pressure transducers. See hydronic module option chapter HP variable-speed single-pump 116V Single high-pressure water pump with hydr onic mod. variable speed drive (VSD), water filter, electronic water flow control, pressure transducers. Multiple possibilities of water flow control. See hydronic module option chapter HP variable-speed dual-pump 116W Dual high-pressure water pump with hydronic mod. variable speed drive (VSD), water filter, electronic flow switch, pressure transducers. Multiple possibilities of water flow control. See hydronic module option chapter J-Bus gateway 148B Two-directional communication board complying with JBus protocol BacNet gateway 148C Two-directional communication board complying with BacNet protocol Lon gateway 148D Two-directional communication board complying with Lon Talk protocol Enviro-Shield anti-corrosion 262 Coating by conversion process which protection modifies the surface of the aluminum producing a coating that is integral to the coil. Complete immersion in a bath to ensure 100% coverage. No heat transfer variation, tested 4000 hours salt spray per ASTM B117 Super Enviro-Shield anti-corrosion 263 Extremely durable and flexible epoxy protection polymer coating applied on micro channel heat exchangers by electro coating process, final UV protective topcoat. Minimal heat transfer variation, tested 6000 hours constant neutral salt spray per ASTM B117, superior impact resistance per ASTM D2794 Evaporator screw connection sleeves 264 Evaporator inlet/outlet screw connection sleeves Welded evaporator water connection 266 Victaulic piping connections with welded kit joints Reinforced ECM filtration for fan VFD 282A Fan variable frequency drive compliance to IEC 61800-3  C1 class Reinforced ECM filtration for pump VFD 282B Pump variable frequency drive compliance to IEC 61800-3  C1 class Power cable connection side extension 283 C A R R I E R 2 0 1 6 / Side extension on the power control to allow a reduced cable bend radius 2 0 1 7 Advantages Use 30RBSY Easy and fast installation, operating safety, reduced power consumption of the water circulation pump 30RBSY 039-160 Easy and fast installation (plug & play) 30RBSY 039-160 Easy and fast installation (plug & play) 30RBSY 039-160 Easy and fast installation (plug & play) 30RBSY 039-160 Easy and fast installation (plug & play) 30RBSY 039-160 Easy and fast installation (plug & play), 30RBSY significant pumping energy cost savings 039-160 (more than two-thirds), tighter water flow control, improved sytem reliability Easy and fast installation (plug & play), 30RBSY significant pumping energy cost savings 039-160 (more than two-thirds), tighter water flow control, improved sytem reliability Connects the unit by communication bus to a building management system Easy connection by communication bus to a building management system Connects the unit by communication bus to a building management system Improved corrosion resistance, recommended for use in moderately corrosive environments 30RBSY 039-160 30RBSY 039-160 30RBSY 039-160 30RBSY 039-160 Improved corrosion resistance, recommended for use in extremely corrosive environments 30RBSY 039-160 Allows unit connection to a screw connector Easy installation 30RBSY 039-160 30RBSY 039-160 30RBSY 039-160 Allows unit installation in domestic residential environment by reducing electromagnetic interferences Allows unit installation in domestic residential environment by reducing electromagnetic interferences Use of thicker power cables 30RBSY 039-160 30RBSY 039-160 111 HEATING HEATING No. AIR TREATMENT Options CONTROLS Options COOLING DUCTABLE AIR-COOLED LIQUID CHILLERS  30RBSY 039-160