Adjustment Instructions for the TROJAN Flag Hinge | Page 3
To adjust the door vent
compression and height
within the frame unclip the
cap as shown
This Bolt is used to adjust
height and compression
Insert 4mm A/F Alan key to
adjust the vent height
within the frame and the
vent to frame compression.
Adjustment available
Height (from lowest Position) +7mm
Compression (from mid position) +/- 1.75mm
Lateral +/- 5mm
Important!
As the Alan Key is turned
clockwise clicks are felt and
the vent will rise. When the
correct height has been
reached the compression
should be adjusted by
additional left or right
clicks. The compression gap
should be set at approx
3mm. To lower the vent
turn anti-clockwise and
repeat the steps.
Adjusting the hinges will not compensate for a door aperture and frame that are out of
square. If The Diagonal measurements shown vary by more than 5mm or the width
measurements vary the Holiday Home should be levelled or the frame installation
corrected. The hinges can then be used to fine tune the door operation. Any adjustment
should normally be made to all hinges; otherwise the door vent could become twisted.
Diagonal Measurement
Width Measurements should be equal
3