MVK FUSION
…is an opportunity to standardize
modular processes, opening the door
to a one-module strategy
IO-Link button
systems
IO-Link inductive
couplers
IO-Link
03
The PROFINET/PROFIsafe module unites three basic
functions of installation technology:
01 Standard digital sensors and actuators
02 Safety digital sensors and actuators
03 IO-Link
Safety
valves
02
Safety
01
Standard IO
MVK Fusion makes complex configurations easier because they can be done entirely by the
engineering tool in the safety control system. Software developers and electrical engineers
no longer need in-depth knowledge of other manufacturers’ tools and manuals.
MVK Fusion makes it possible to have fewer fieldbus modules per unit. Some applications
might only require a single module. This opens up new opportunities for many automation
applications!
What makes the MVK Fusion field-
bus module unique is its variety.
It combines three basic functions: standard digital
sensors and actuators, safety digital sensors and
actuators and IO-Link.
• The two standard digital ports can be config-
ured as inputs or outputs – they are customiz-
able for each application.
• The four safety ports ensure that almost all
digital safety requirements are integrated into
the installation.
• The two IO-Link ports offer a wide range of
functions: they integrate smart devices into the
fieldbus system and they also enable the sys-
tem to be expanded cost-effectively via IO-Link
hubs.
MVK Fusion simplifies installation by minimizing
the number of modules required.
Safety door
systems
IO-Link
hubs
IO-Link distance sensors
IO-Link
pressure sensors
This combination is new and innovative. It enables unique and
groundbreaking automation concepts to be realized. Installation becomes
simpler and faster.
One Module with
Extreme Range
IO-Link
valve islands
Flexibility within
Safety Applications
MVK Fusion integrates all safety
aspects into one module:
• Safety sensors signals are transmitted over the
three safe input ports, each of which have two
channels. Emergency stop buttons, light cur-
tains, two-handed units, safety doors, etc. can
be qualified up to Performance Level e.
• The safety output port has two safe outputs
that can be configured according to the ap-
plication (PP, PM or PPM switching). You can
integrate a wide variety of actuator types like
double valves and valve islands that still qualify
up to Performance Level e.
• A special Class B IO-Link port ensures that IO-
Link devices like valve islands and hubs can be
easily and safely switched-off complying with
safety standards up to Performance Level d.
MVK Fusion lets you achieve high safety standards,
protecting both man and machine.
Electromechanical
safety switches
IO-Link
transponder
systems
Two-handed
devices
Safety Configuration within
a Mouse Click
MVK Fusion makes configuring
safety sensors and actuators ex-
tremely easy: select the safety function in the safety
control system engineering tool, and within a few
mouse clicks configuration is done.
The users – usually the software developer or the
electrical engineer – do not require any special
know ledge to configure the module. The MVK
Fusion module eliminates the extra verification
work step (CRC calculation) and doesn’t require
additional manufacturer-specific software. This
speeds up the process because it prevents entry
of incorrect data.
High Performance
MVK Fusion is excellent for high
power applications when reliability
cannot be compromised. The module
is one hundred percent compatible with PROFINET
solutions. MVK Fusion is suitable for Conformance
Class C (IRT), Shared Device and Netload Class III
applications.