| Wash 185 FSD Series Inline Mixed Flow Square Fans Fantech, Inc. certify that the Ventilators shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCACertified Ratings Program. The FSD Series is a mixed flow centrifugal type exhaust/supply fans for moderate size ventilation applications were specifically designed to provide the high flow of axial designs plus the higher pressure, non-overloading characteristics of backward curved impellers. Motor bearings are a permanently sealed, self-lubricating ball type. The square design provides a larger discharge area than tubular centrifugal or vane axial fans, so outlet velocitites are reduced for quieter operation. • • • • • Airflow up to 6993 cfm Lightweight square design provides a larger discharge area and quieter operation Mixed flow impeller design incorporates high flow with higher pressure, non-overloading characteristics and automatic reset thermal overload protection 100% speed controllable Airstream temperatures of up to 140° F Specification data Rated power Voltage / phase RPM W V/~ min-1 A FSD 18 517 120 / 1 1700 FSD 20 753 120 / 1 FSD 22 1554 120 / 1 FSD 26 2328 460 / 3 Model Max. apms 0.0” Ps .25” Ps .50” Ps .75” Ps 4.802 2463 2237 1987 1600 6.36 3225 2921 1600 15.003 5223 4918 1700 3.82 6993 6644 1.0” Ps 1.5” Ps 2.0” Ps Sones† 1644 1180 - - 12.4 65 40035 965.00 2605 2241 1829 815 - 14.1 81 40036 1,550.00 4605 4282 3865 2716 1308 21.0 111 40037 2,168.00 6317 5981 5608 4681 3469 27.0 134 40038 2,810.00 cfm 2 2 Shipping weight Item # lbs ‡ List price USD Performance certified is for installation type A - Free inlet, free outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories). Note: Three phase motors are wound for 230/460 volt. Motors are prewired for 460 volts but may be delivered as 230 volt or may be rewired in the field. † The sound ratings shown are loudness values in fan sones at 5ft. (1.5m) in hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet hemispherical fan sone levels. All sone values are calculated at 0.5” (static pressure in inches W.G.). ‡ Sone Value at 0.75” (static pressure in inches W.G.). 2 Recommended speed control rating 10A 3 Recommended speed control rating 15A fantech