118 2-2. Charging
When charging cannot be carried out
When charging does not start, even though the normal procedure is followed, check each of the following items.
If a message is shown on the multi-information display, also refer to P. 124.
When charging cannot be carried out
Refer to the following table and carry out the appropriate correction procedure.
n Charging indicator of the charging port does not illuminate, even though AC charging connector is connected.
Likely cause
AC charging connector is not securely connected to AC charging inlet
Traction battery is already fully charged
The remaining charge of the traction battery exceeds the set upper limit of the charge capacity
The AC charger does not operate
Correction procedure
Check the connection status of the charging connector. � When connecting the AC charging connector, insert the AC charging connector securely.
� After connecting the AC charging connector, check that the charging indicator of the charging port is turned on.
If the charging indicator of the charging port does not illuminate, even though the AC charging connector is securely connected, there may be a malfunction in the system. Immediately stop charging and contact your SUBARU retailer.
When the traction battery is fully charged, charging is not performed.
Change to a higher upper limit setting than the current remaining charge capacity and perform charging again.
Please contact the facility manager when there is a problem with AC charger.